Alaska Boiler & Furnace Error Code Lookup & 2026 Repair Estimator

Look up your exact Navien, Weil-McLain, Burnham, Lochinvar, Toyotomi, or forced-air furnace error code below—including what causes it during sub-zero Alaska weather and typical 2026 repair costs.

Instant Boiler & Furnace Error Code Filter

Type an error code (e.g. E003, E012, E110, 30 PSI, 3 flashes) or brand name to filter the table below:

Call 24/7 Tech: (907) 250-9156
Brand / System Code / Symptom Meaning & Alaska Winter Cause Professional Fix 2026 Cost Range
Navien E003 Ignition Failure (No Flame Detected) Gas shutoff closed, failed igniter rod, dirty flame sensor rod, or frozen condensate drain backing up into combustion chamber. Clean/replace igniter & flame rod, thaw condensate trap, verify Enstar gas inlet pressure. $295 – $580
Navien E012 Flame Loss During Operation Snow/hoarfrost blocking outdoor PVC intake/exhaust vent, fluctuating gas pressure, or grounded flame rod. Clear exterior snow drift from vent, inspect vent slope, clean flame sensor & test gas valve. $295 – $550
Navien E016 Overheating of Heat Exchanger Frozen hydronic baseboard loop, airlocked zone, seized Taco/Grundfos circulator pump, or clogged internal Y-strainer. Thaw frozen zone loop, bleed air, clean strainer & replace failed circulator pump. $385 – $950
Navien E109 / E110 Fan Motor or Air Pressure Switch Fault Exterior PVC exhaust/intake iced over by sub-zero wind or failed combustion blower/APS tubing. Clear ice plug from concentric/twin-pipe termination & test air pressure switch. $295 – $690
Navien E302 Low Water Pressure in Boiler Loop (< 6 PSI) Failed Watts 1156 feed valve, air bleed loss, or hidden hydronic baseboard leak. Feed system to 12–15 PSI, inspect for loop leaks & replace automatic fill valve. $325 – $680
Weil-McLain / Burnham Solid Red Lockout LED (Aquastat) Electronic Ignition / Flame Rollout Lockout Failed intermittent pilot igniter, bad Honeywell L8148E/L7224U aquastat relay, or tripped rollout/spill switch. Test 24V ignition module, replace pilot assembly or aquastat control board. $350 – $890
Weil-McLain / Burnham 30 PSI + Dripping Relief Valve Ruptured Expansion Tank Bladder Waterlogged #30 hydronic expansion tank causes pressure to spike above 30 PSI when boiler heats to 180°F. Replace #30 diaphragm expansion tank (pre-charged to 12 PSI) & replace 30 PSI ASME relief valve. $420 – $780
Lochinvar / Viessmann LOC / Ignition Lockout 3 Failed Ignition Attempts or Blocked Condensate Frozen condensate line, snow-blocked intake, or worn spark electrode. Thaw condensate line, replace electrode/sensor & verify combustion CO2/O2. $325 – $750
Goodman / Carrier / Trane Furnace 3 Flashes / Pressure Switch Open Inducer Draft Pressure Switch Did Not Close Roof/wall exhaust vent frosted shut, cracked rubber pressure hose, or seized inducer fan motor. Clear roof/wall vent frost, clear condensate trap, or replace inducer draft motor. $295 – $780
Goodman / Carrier / Trane Furnace 4 Flashes / High Limit Open Primary Heat Exchanger Overheated Severely clogged air filter, failed indoor blower motor/capacitor, or blocked supply registers. Replace filter, test run capacitor (mFd), or replace blower motor. $295 – $750
Toyotomi / Rinnai (Laser 56 / 73) E-2 / E-6 Failed Ignition or Flame Extinction Gelled outdoor heating oil line at -20°F, carboned igniter/burner mat, or water in fuel strainer. Thaw fuel line, clean fuel strainer, or replace igniter/burner ring. $295 – $680
Common Questions & Answers

Alaska Boiler & Furnace Error Code FAQs

Direct answers to common questions about our property maintenance, repairs, and 24/7 emergency services.

Need Quick Answers? Call (907) 250-9156

On Navien NCB combi-boilers and NHB heating boilers in Anchorage and Wasilla: E003 is ignition failure, E012 is flame loss (often a snow-blocked outdoor PVC vent), E016 is overheating (often a frozen baseboard loop or dead circulator pump), E109/E110 is exhaust fan or air pressure blockage, and E302 is low water pressure. Call Anchor Services Alaska 24/7 at (907) 250-9156.

Never press a boiler or furnace reset button more than once. Repeatedly resetting an ignition lockout can flood the combustion chamber with unburned fuel or overheat a dry/frozen heat exchanger.