Skip to main content
Anchor Services Alaska
All Alaska Case Studies / Knik-Goose Bay (KGB) / Settlers Bay (99623)
📍 Knik-Goose Bay (KGB) / Settlers Bay, Wasilla (99623) ❄️ Outdoor Temp: -24°F ⏱️ Dispatch Arrival: 64 Minutes

Case Study: -24°F Frozen Well Switch & Navien E016 Overheat Repair in Wasilla (99623)

The Emergency Situation (Knik-Goose Bay (KGB) / Settlers Bay, Wasilla)

An unsealed foundation vent in the northwest crawlspace corner allowed -24°F wind to freeze both the private well pressure switch sensing tube and a hydronic return line feeding the garage unit heater.

🔧 Square D Pumptrol 40/60 Pressure Switch & Liquid Gauge 🔧 Commercial Self-Regulating Heat Trace Cable 🔧 Navien Flow/Strainer Service Kit

✅ Result: Restored both domestic well water and whole-house hydronic heat in one visit without needing a separate well contractor and HVAC company.

How Our "One-Call" 3-Phase Recovery Executed the Fix

Phase 1: Protecting the Submersible Well Pump & Restoring Water Pressure

We isolated the 240V well breaker, thawed the crawlspace well manifold, replaced the corroded 1/4-inch steel sensing nipple with a brass tee and new Square D 40/60 pressure switch, and restored 55 PSI domestic water across the home.

Phase 2: Resolving Navien NCB-240E Error Code E016

We cleaned the Navien internal heating Y-strainer, thawed the restricted garage zone loop, purged trapped air, and verified smooth circulation across all three heating zones.

Phase 3: Permanent Crawlspace Freeze-Proofing

We installed commercial self-regulating heat trace cable on the well entry manifold and insulated the foundation rim joist with 2-inch rigid foam board.

Common Questions & Answers

Knik-Goose Bay (KGB) / Settlers Bay Case Study FAQs

Direct answers to common questions about our property maintenance, repairs, and 24/7 emergency services.

Need Quick Answers? Call (907) 250-9156

Because Anchor Services Alaska cross-trains and licenses our emergency crews in both Alaska hydronic heating systems and domestic well/house plumbing—so Mat-Su homeowners don't have to pay two separate call-out fees.